Creating and Tuning of DeviceLink profiles

Creating and Tuning of DeviceLink profiles

To improve the color accuracy of your proofs, you can create and use a DeviceLink profile. A DeviceLink is a link between the reference profile and the printer profile of your queue. The DeviceLink profile directly transforms color from one color space to another, without using an intermediate, device-independent color space (CIELab).

 

In the RIP a DeviceLink is created on the fly and stored in the PMM.

Tune a variant-reference combination to get a very close proofing result

Tuning of a DeviceLink is performed to bring back the profile to ‘the golden state’.  the K is kept and the CMY combinations are tuned.

Tuning a DeviceLink can improve the delta E values for proofing and can make color reproduction more accurate through an iterative process. However, tuning can only be effective if the following conditions are met:
    • The reference profile must be suitable for proofing on the printer with the respective media. If not, the combination of the reference profile with the printer profile may not be optimal.
    • The quality of the printer profile must be good enough.
Proceed as follows
  1.  Select the VISU variant for which you want to tune the DeviceLink
  2. Click Tune DeviceLink
  3. Check Printer settings and reference profile
  4. Click Next
  5. Select and connect the Spectrophotometer and check media size
  6. Select the target’s position and orientation and click OK.
  7. Press Print
  8. Measure the printed DeviceLink Target
  9. Click Next.An overview of all measured patches is displayed, with their respective refer- ence and measured Lab values, and the difference between both as delta E values.
  10. Click Next.
    A summary of the delta E statistics is displayed:

    • If this is the first proof which you printed and measured, this set of measurements will be called “Initial State“. This is the current status “as is”, without any adjustments made.
    • If this is the second proof and measurement, the set of measurements will be called “Measurement1“, indicating that these are the first adjustments you have made.The results are set against a certification standard – default is set to ISO-12647-7, but you can select any of the following:
      • Offset
      • Newsprint
      • Gravure
      • Screen Printing
      • ISO-12647-7
      • ISO-12647-7 Validation print
        or
      • Create a new set with custom defined Delta E settings
  11. You can now do one of the following:
    • If the results are not satisfactory – Delta E set to FAIL , click Refine.
      ->The target will automatically be reprinted and you can then measure this refined target again. Repeat this step a number of times, typically three to four times, until the results are satisfactory.
    • If the results of a particular set of measurements are satisfactory, select the set in the list and click Finish. For example, you may have four sets of measurements, of which the set “Measurement3” had the best results. If so, select “Measurement3” in the list and click Finish.


    • Related Articles

    • Create Device Link

      VISU profiles are Device Link (DL) Profiles. A Device Link profile converts color from one space to the individual printer’s color space without begin converted to an intermediate color space. Click here for more background info. This video shows how ...
    • Managing Measurement Devices When Creating Multiple PMMs Simultaneously

      Overview: PrintFactory Calibrator allows for the simultaneous creation of multiple profiles (PMMs). However, it's crucial to be aware of the limitations regarding changing measurement devices and settings during these sessions. Device Limitation: ...
    • Tune a Device Link

      This video shows how to tune a Device link to obtain a closer match proof.
    • Creating Objects

      Creating a Circle from Three Points You can create a circle or a circular path by defining three points in your document. How to create a circle by selecting three points 1. Select the Circle tool from the Tools panel. 2. Click at three positions on ...
    • Xrite i1 Device connection/reading issues

      Connection issues The i1 devices are known to be sensitive to low powered USB ports. Those port are common on MacBook and other laptop computers. Using these devices (even the separately powered i1 iO) with a low power USB port result in the ...